1050S 50MHz Digital Storage Oscilloscope
-
Model No.
1050S
1100S
Bandwidth
50MHz
100MHz
Channel
2
2
Acquisition
Mode
Normal, Peak detect, Averaging
Sampling Rate (real time)
500 MS/s
1 GS/s
Input
Input coupling
DC, AC , Ground
Input impedance
1 MΩ±2%, in parallel with 20 pF±5 pF
Input coupling
1X,10X,100X,1000X
Max. input voltage
400V (DC+AC, PK - PK)
Channel –channel isolation
50Hz: 100 : 1 / 10MHz: 40 : 1
Time delay between channel(typical)
150ps
Bandwidth limit
Not support
20 MHz, full bandwidth
Horizontal System
Sampling rate range
0.5 S/s~500 MS/s
0.5 S/s~1 GS/s
Interpolation
(Sinx)/x
Max Record length
10K
Scanning speed (S/div)
2 ns/div – 1000 s/div, step by 1 – 2 - 5
Sampling rate / relay time accuracy
±100 ppm
Interval(△T) accuracy
(DC -100MHz)
Single:±(1 interval time+100 ppm×reading+0.6 ns);
Average>16: ±(1 interval time +100 ppm×reading+0.4 ns)Vertical system
Vertical Resolution (A/D)
8 bits (2 channels simultaneously)
Sensitivity
5 mV/div~5 V/div
Displacement
±2 V (5 mV/div – 100 mV/div)
±50 V (200 mV/div – 5 V/div)Analog bandwidth
50MHz
100MHz
Single bandwidth
Full bandwidth
Low Frequency
≥10 Hz (at input, AC coupling, -3 dB)
Rise time (at input, Typical)
≤ 7.0 ns
≤ 3.5 ns
DC gain accuracy
±3%
DC accuracy (average)
Delta Volts between any two averages of
≥16 waveforms acquired with the same scope
setup and ambient conditions (△V): ±(3% reading + 0.05 div)Waveform inverted ON/OFF
Measurement
Cursor
△V, △T, △T&△V between cursors, auto cursor
Automatic
Period, Frequency, Mean, PK-PK, RMS, Max,
Min, Top, Base, Amplitude, Overshoot, Preshoot,
Rise Time, Fall Time, +Pulse Width, -Pulse Width, +Duty Cycle, -Duty Cycle, Delay A→B , Delay A→B , Cycle RMS, Cursor RMS, Screen Duty, Phase, +Pulse Count, -Pulse Count, Rise Edge Count, Fall Edge Count, Area, and Cycle Area.Waveform Math
+, -, *, / ,FFT
Waveform storage
16 waveforms
Lissajous figure
Bandwidth: Full bandwidth / Phase difference:±3 degrees
Trigger
Trigger level range
Internal:±5 div from the screen center
Trigger level accuracy (typical)
Internal:±0.3 div
Trigger displacement
According to Record length and time base
Trigger Holdoff range
100 ns – 10 s
50% level setting (typical)
Input signal frequency ≥ 50 Hz
Edge trigger
slope: Rising, Falling
Video Trigger
Modulation: Support standard NTSC, PAL and SECAM broadcast systems
Line number range:1-525 (NTSC) and 1-625 (PAL/SECAM)Communication
USB 2.0 (USB storage)
Counter
Support
General Information
Temperature
Working temperature: 0 ℃ - 40 ℃
Storage temperature: -20 ℃ - 60 ℃Relative humidity
≤ 90%
Height
Operating: 3,000 m
Non-operating: 15,000 mCooling Method
Natural cooling
Probe compensator output Voltage
About 5 V, with the Peak-to-Peak voltage ≥1 MΩ.
Probe compensator output frequency
Square wave of 1 KHz
LCD size
7" Colored LCD
Display resolution
800 (Horizontal) × 480 (Vertical) Pixels
Display color
65536 colors, TFT screen
Power supply
100 - 240 VACRMS, 50/60 Hz, CAT Ⅱ
Power Consumption
< 15 W
Fuse
2 A, T class, 250 V
Product Dimension
301 mm× 152 mm×70 mm (L*H*W)
Product weight
About 1.1 kg
Standard Accessories
Power Cord, Software CD, User Manual , USB cable ,Probe , probe adjust . Pouch (Optional)
-
*2 Channels
*500 MS/s sampling rate
*7" Colored TFT screen , 800*480 resolution
* Max Record length up to 10K
* 30 kinds of different automatic measurements
* Ultra light weight design , easy to carry