6415 Double Clamp Grounding Resistance Tester
-
Specification
Function
4-pole, 3-pole ,2-pole, selection, double clamp method measure grounding resistance,
Soil Resistivity;
Earth Voltage,
AC Voltage,
AC Leakage Current
Parameters
Range
Accuracy
Resolution
Selection Method
0.00Ω-30.00Ω
±2%rdg±3dgt
0.01Ω
30.00Ω-300.0Ω
0.1Ω
300Ω-3000Ω
1Ω
Double Clamp Method
0.01Ω-1.00Ω
±10%rdg±5dgt
0.1Ω
1.0Ω-10.0Ω
0.01Ω
10Ω-100Ω
1Ω
2/3/4 Pole Method
0.00Ω~30.00Ω
±2%rdg±3dgt
0.01Ω
30.0Ω~300.0Ω
0.1Ω
300Ω~3000Ω
1Ω
3.00kΩ~30.00kΩ
±4%rdg±3dgt
10Ω
Soil Resistivity
0.00Ωm~99.99Ωm
According to the precision of R
(ρ=2πaR
a:1 m-100m,
π=3.14)
0.01Ωm
100.0Ωm~999.9Ωm
0.1Ωm
1000Ωm~9999Ωm
1Ωm
10.00kΩm~99.99kΩm
10Ωm
100.0kΩm~999.9kΩm
100Ωm
1000kΩm~9000kΩm
1kΩm
Earth Voltage
0.0V~100.0V
±2%rdg±3dgt
0.1V
AC Current
0.00mA~600A
±2%rdg±3dgt
0.01mA
Measuring Mode
Precise 4-pole measurement,
3-pole measurement,
simple 2-pole measurement,
selection method,
double clamp method
Measuring Method
2/3/4 pole method: change-pole method, measurement current 20mA Max
Selection method: change-pole method, measurement current 20mA Max
Double clamp method: disconnect mutual inductance method, measurement current 1mA Max
Soil Resistivity: 4-pole measurement (Wenner method)
Earth Voltage: average rectification(between P(S)-ES)
AC current: mutual inductance method
Test Frequency
128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current
AC 20mA max
Open-circuit Test Current
AC 40V max
Test Voltage Wave
Sine wave
Electrode Distance Range
1m-100m
Features
Operation Way
Auto Range
Backlight
√
Display
4-digital large LCD ,124mmx67mm
Clamp Size
Φ68mm
Measuring Indicator
LED flash / LCD countdown / analog bar
Sampling Rate
Voltage to ground: 2 times/s
Current to ground: 2 times/s
Earth resistance, soil resistivity: 5 seconds/time
Measuring Times
Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Interface
RS232
Data Storage
2000 groups
Data Hold
√
Over range indication
“OL” display
Interference Test
Automatically, interference voltage > 5V : “NOISE” display
Auxiliary Earth Test
Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm
√
Low Battery Indication
√
Auto Off
15minutes idle
Working Condition
-10℃-40℃, < 80%RH
Storage Condition
-20℃-60℃, <70%RH
Insulation
Over 20MΩ (between circuit and enclosure it is 500V)
Withstanding Voltage
AC 3700V/rms. (Between circuit and enclosure)
Electromagnetic Features
IEC61326(EMC)
Safety
IEC61010-1 (CAT Ⅲ 300V、CAT IV 150V、Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004
General Information
Power Supply
R14S 1.5V 6 PCS
Product Size
215mm×190mm×95mm
Product Weight
Total weight: 8.0kg (including package)
Tester: 1653g (including battery)
Testing wires: 1560g
Auxiliary earth rods: 935g (4pcs)
Standard Accessories
Clamp x2pcs , Manual x 1pc , Test Wires (red 20m, black 20m, yellow 10m, green 10m) ,Short Test leads (red 1.6m , black 1.6m) , Earth Rod (Φ10mm×150mm)x4pcs , RS232 Cable + Software CD x 1pc , Tool Case x 1pc
-